DM-700 O2

Detcon The DM-700-O2 is a non-intrusive "smart" sensor designed to detect and monitor oxygen in the air over a range of 0 to 25% by volume using electrochemical sensor technology. The plug-in, field-replaceable sensor cell is temperature compensated and features oversized gold-plated connections that help prevent corrosion.

The sturdy frame of the 700 model features an intrinsically safe, polished 316 stainless steel case with fully encapsulated electronics and double-layer surge protection. This innovative design virtually eliminates sensor failure due to water ingress, corrosion, vibration and transient spikes.

A key feature of the Model 700 is an intuitive, built-in software that simplifies the operator interface by guiding the user through the usual calibration, configuration, and troubleshooting functions using an alphanumeric display integrated. The Model 700 is equipped with standard 4-20 mA analog outputs and Modbus ™ RS-485 outputs.

Among its unique features, a wireless option can be used with the Detcon SmartWireless® product line. Additional integration options include a Remote Alarm Module (RAM), HART, and Foundation Fieldbus. Detcon's oxygen sensors have a long service life and are backed by a first-class warranty.

 

Failsafe user-friendly interface

  • LED display (with anti-glare)

  • Full-text display method

  • Non intrusive interface

  • Auto Zero / Auto Span

  • Preventive diagnosis of defects

Eco-friendly bulletproof

  • Electropolished 316SS construction

  • Circuits encapsulated with 100% epoxy

  • Bulletproof I / O protection

  • Waterproof, corrosion resistant, vibration resistant

Modular and repairable

  • Modular design

  • Plug and Play Components

  • Quick release of thread (for sensor replacement) I

  • Ntegral calibration port

Sensor type

Continuous diffusion / adsorption

Electrochemical cell with 2 electrodes

Smart type replaceable plug-in

Sensor life

Typical 2 1/2 to 3 years

Measuring range

0-25% oxygen by volume

Precision / Repeatability

±1% FS

Response/compensation time

T90 ≤ 10 seconds

Span Drift

<5% of the signal per year (in the first two years)

Outputs

Linear 4-20 mA DC

RS-485 MODBUS-RTU

Electrical classification

Explosion

cCSAus (NRTL)

Class I, Division 1, Groups B, C, D (Tamb = -40 ° C to + 50 ° C)

Class I, Zone 1, Group IIC

ATEX

II 2 G Ex d ib IIC T4 Gb (Tamb = -40 ° C to + 50 ° C)

Protection against ingress

NEMA 4X, IP66

Security approvals

cCSAus

ATEX

CE marking

SIL2 certified according to IEC 61508

warranty