Data sheet

DM-600-SO2

The Detcon Model DM-600IS-SO2 Detector is designed to detect and monitor SO2 in air in the 0-20 ppm range.

The sensor assembly consists of an electrochemical fuel cell mounted in a stainless steel and ABS plastic casing incorporating a splash guard with integrated heat port, a signal conditioning control transmitter circuit, a base board and a explosion-proof junction box.

The intrinsically safe sensor housing design allows direct contact of the target gas with the electrochemical sensor, maximizing response time, detectability and repeatability.

And because the intrinsically safe case design does not use stainless steel flame arresters, it eliminates inaccurate readings due to target gas absorption.

  • Homologué CSA et UL: Classe 1, Div. 1, Groupes B, C et D

  • Sorties: 4-20 mA, RS-485 Modbus ™, 3 relais (2 alarmes, 1 défaut)

  • Etat du capteur et paramètres accessibles via RS-485 Modbus ™

  • Calibrage piloté par menu simple - prend moins de 3 minutes

  • Écran LCD rétro-éclairé et voyants LED pour défaut et état Cal

  • Transmetteur universel

  • Boîtier de capteur à sécurité intrinsèque

  • Plug-in émetteur remplaçable

  • Capteur électrochimique enfichable

Type de capteur

Pile à combustible électrochimique

Plage de mesure

0-20 ppm de dioxyde de soufre

Autres gammes disponibles

Répétabilité

±2% FS

Réponse / temps de compensation

T90 ≤20 seconds

Span Drift

<2% de perte de signal par mois

Plage de température de fonctionnement

De -20 ° C à + 50 ° C; -4 ° F à + 122 ° F

Plage d'humidité de fonctionnement

15-90% HR sans condensation

Sortie

Linéaire 4-20 mA DC

RS-485 Modbus ™

3 relais (alarme 1, 2, défaut, contacts 5 ampères)