The Detcon Model DM-534 Detector is designed to detect and monitor O2 in air over a range of 0 to 25% by volume.
The sensor assembly is comprised of an electrochemical fuel cell mounted in a stainless steel housing that includes a splashguard with an integrated heat port, a signal conditioning control transmitter circuit, a base connection board, and an explosion-proof junction box.
The operator interface is via a small pocket magnet. One of the key features is the intuitive, built-in software that guides the user through routine calibration and setup menus using an integrated alphanumeric LED display.
CSA-NRTL Listed: Class I, Division 1, Groups B, C and D
4-20 mA output
Simple Menu Driven Calibration - takes less than 3 minutes
Backlit LCD display and LEDs for fault and Cal status
Pluggable field replaceable transmitter
Electrochemical pluggable sensor
Built-in temperature compensation provides a direct correction to changes in ambient temperature
Expected sensor life of 2 years in the air with 20.9% oxygen
Sensor type |
Galvanic metal air coil |
Measuring range |
0-25% oxygen |
Precision / Repeatability |
±1% FS |
Operating temperature range |
From -20 ° C to + 50 ° C; -4 ° F to + 122 ° F
|
Operating humidity range |
0-99% RH without condensation |
Input voltage |
11.5-28 VDC |