Data sheet

AirAware

Industry proven performance combined with a low-profile design make a logical choice for those areas that require continuous monitoring but not the environmental protection of an explosion-proof enclosure.

Providing discrete monitoring and enhanced aesthetics for more commercial or institutional settings, the AirAware Series is the ideal solution for reliable, low-cost fixed-point monitoring.

The AirAware can be configured to operate as a monitor with local LED display, a controller with onboard relay switching capability, a transmitter with 4-20 mA or ModBus RTU outputs, or as a transmitter with on-board relays.

Each configuration is designed to meet your specific indoor monitoring needs. Every AirAware is equipped with electrochemical sensing technology, dual alarm LEDs, push-button operation and a NEMA 4 type enclosure.

Configure your AirAware to match your needs, adding options such as a vanity plate to hide the display.

The AirAware is covered by a one-year warranty and carries CSA approval for non-hazardous locations.

  •  Institutional, commercial and light industrial monitoring

  • Monitor any one of nine gases

  • Simple installation using 12-24 VDC operation, or an optional AC power adapter that plugs into any standard 120 VAC wall outlet (North American plug).

  • Bright display constantly shows gas concentrations

  • Single button calibration, alarm muting and zero functions

  • Visual alarm to alert of potential gas hazards (audio optional)

  • ModBus digital output (4-20 mA output optional) for interfacing with control devices

  • Optional dual-alarm relays can turn on fans and warning sirens, or shut-down a process.

Case:

NEMA 4 type, General purpose indoor use. Electroplated for RFI protection

Dimensions:

18.29 cm x 14.22 cm x 4.06 cm (7.2′′ x 5.6′′ x 1.6′′ )

Weight:

454 g (16 oz)

Sensor Type:

Electrochemical

Measuring Ranges:

Carbon Monoxide, Hydrogen Sulfide – 0 to 999 ppm in 1 ppm increments
Nitric Oxide – 0 to 999 ppm in 1 ppm increments
Ammonia – 4 to 100 ppm in 1 ppm increments
Oxygen – 0 to 30% by volume in 0.1% increments
Sulfur Dioxide, Nitrogen Dioxide – 0.2 to 99.9 ppm in 0.1 ppm increments
Chlorine – 0.2 to 50 ppm in 0.1 ppm increments
Hydrogen Chloride – 0.2 to 30 ppm in 0.1 ppm increments

Power Source (Run Time):

12-24 VDC (110 AC adapter optional with North American plug)

Temperature Ranges:

-20°C to 50°C (-4°F to 122°F ) typical, consult factory for gas specific temperature ranges

Humidity Range:

Oxygen – 0-99%
Ammonia, Carbon Monoxide, Hydrogen Sulfide, Nitrogen Dioxide, Sulfur Dioxide – 15-90%

Approvals:

CSA – C.22.2 No. 205-M 1983 (non-hazardous locations); CE (pending)